[ VinDiesel @ 15.02.2004. 00:38 ] @
Dakle problem je slececi:
-Maxtor Fireball 3!

Sta nije u redu?
-Bios ga prepoznaje svaki 100-ti put kao Maxtor(64K -pa sad nesto bez veze)

Inace, ovo nije moj hdd (od nekog ortaka je, a on kaze kako je virus izbrisao bios hdd-a).
Probao sam na vise ploca ali bezuspesno...

Ni powmax ne radi...

More info: Motor radi ok, glava se ne cuje, elektronika (izgleda) ok.


Aj ljudi pomagajte! Pa nije valjda da niko ne zna?! Ako je crko slobodno recite...


BeastMaster: Promenjen naziv teme, a da bi u buduće što pre dobio pomoć/odgovor potrudi se da adekvatno nazoveš temu.



[Ovu poruku je menjao BeastMaster dana 19.02.2004. u 20:34 GMT]
[ VinDiesel @ 19.02.2004. 18:28 ] @
Alo bre, sta da radim? da bacim hdd ili da ga nosim u servis...
[ insomniac_st @ 19.02.2004. 19:36 ] @
Elektronika radi OK ali ako BIOS javi: npr. primary master hard disk failed, tesko da ima spasa. Inace, HDD nema BIOS. Ako ga BIOS ispravno prepozna i ako je sve dobro namjesteno (boot) onda nema razloga da se OS ne digne sa diska. Kad si probao na vise racunala i nije valjao, sada ga pokusaj bacit u smece :)
Ako imas neke vazne podatke (slucajno) onda se ipak moze iscitat sadrzaj diska (otidi do servisa) pomocu elektronskog mikroskopa.
[ djolep @ 19.02.2004. 21:44 ] @
Ako ga ni PowerMax ne vidi onda je mrka kapa. Možda neki servis može da pogleda elektroniku.
[ VinDiesel @ 19.02.2004. 22:23 ] @
Ok. Hvala vam.
[ Carnivore @ 19.02.2004. 22:45 ] @
E svasta.... poslao sam poruku prije par sati a tek sad sam vidio da nesto nije u redu. Dakle, evo ponovo....

Probaj da zamijenis elektroniku na HDD-u (uzmes ispravnu s drugog diska). To ti je ona ploca s donje strane HDD-a. Tako ces bar biti u mogucnosti da presnimis podatke koji ti trebaju. Provjereno radi.
Evo ti dio e-maila koji je jedan moj prijatelj dobio od MAXTOR-ovog tehnicara



Maxtor does not sell circuit boards or any other parts.

Please be aware that the warranty (if still valid) will be voided if you replace the circuit board.


To replace the circuit board on all Quantum and SCSI Hard Drives (up to and including the Atlas 10K III): Example GTLA or P/N ZZ10ayyz-xx-x (or ZZ10ayyz Rev. xx-x). ZZ and z have to be the same as the original drive, otherwise it is not possible to replace the circuit board. The same format applies to models DiamondMax Plus D740X, DiamondMax D540X-4K, here the relevant number is called Maxtor GTLA.

For the following Maxtor hard drive models: Fireball 3, DiamondMax 16, DiamondMax Plus 8, and DiamondMax Plus 9 there is also a GTLA Number on the model (next to barcode on the bottom of the drive). Format 1Y222J2223322. 1, 2 and 3 stand for numbers, Y and J for letters. The numbers 1 and 3 as well as the letter Y need to be identical to be able to replace the PCB on these drives.

To replace the circuit board on all other Maxtor drives the drives need to have the same PCBA uplevel number (which describes the revision of the circuit board) and need to be from the same drive family (e.g. Diamond Max 60 or D540X-4D).

They don't need to have the same capacity. You can find the model numbers of particular product families on our website. Under the following link http://www.maxtor.com/en/support/products/index.htm select your specific drive and it should show all model numbers of the same family.

The following link should help you locate the correct numbers:
https://maxtor.custhelp.com/cgi-bin/maxtor....php?p_faqid=824
[ pctel @ 20.02.2004. 22:19 ] @
Citat:
insomniac_st:
Ako imas neke vazne podatke (slucajno) onda se ipak moze iscitat sadrzaj diska (otidi do servisa) pomocu elektronskog mikroskopa.



Taj mikroskop cita sve podatke ili samo tekstualne?
[ insomniac_st @ 23.02.2004. 11:07 ] @
Nisam toliko upoznat sa tom tehnologijom ali znam da je izvodiva. Prijatelju mi se to dogodilo (pokvario mu se disk) i u servisu su mu pomogli da dode do podataka. Podaci su sve sto se nalazi na disku, nema veze kojeg su formata jer sta racunalo zna je li podatak tekstualni file ili film, njemu su to sve nule i jedinice... :))
[ pctel @ 23.02.2004. 18:10 ] @
da, ali ne radi se o optickom vec o magnetnom disku!
[ insomniac_st @ 24.02.2004. 09:12 ] @
To nije vazno, podaci se upisuju u istom obliku (digitalnom), iz magnetskog medija je moguce hardverski ocitati podatke (pomocu elektronskog mikroskopa) jer je to tako konstrukcijski omoguceno.
[ djolep @ 29.02.2004. 20:50 ] @
Zanimljivo.

This image is made using a magnetic force microscope, which uses the motion of a tiny magnet-tipped cantilever to detect magnetic fields emanating from a surface. The field of view is 1.85 microns, less than 1/50th the diameter of a human hair.
[ pctel @ 29.02.2004. 21:42 ] @
OK, samo "elektronski mikroskop" nije dobar naziv, jer je to naziv za drugi uredjaj.
[ Chumby @ 16.06.2004. 01:31 ] @
Uzmi On-Track Disk Manager, v7.02, i prvo formatiraj hdd s njime ne 'quick' vec full
onda napravi particiju 1.
i raditi ce ti.
Neki Boot virusi znaju uciniti prvi sector nevidljivim, pa ga bios ne moze detektirati sectors, heads ... itd.