[ drdrdr @ 26.08.2004. 20:24 ] @
Kako odvajam moju instalaciju ili mrezu od ostatka elektroenergetskog sistema kada pravim mrezu preko strujnih uticnica?
[ Gojko Vujovic @ 27.08.2004. 02:15 ] @
Kažu da ne prolazi kroz brojilo, ali nismo probali.
[ Mihailo @ 27.08.2004. 04:51 ] @
O'Reilly Wireless hacks:

Citat:

Powerline Ethernet won't cross a power transformer, so your network signal usually stops at the end of your house wiring.
[ AleksandarS @ 31.08.2004. 19:12 ] @
Steve Gardner (HomePlug TWG Chair) kaze:

"The topology of power distribution to the home is another factor that must be considered. In a typical US neighborhood, a distribution transformer provides power to a relatively small number of homes (perhaps six). The distribution transformer effectively blocks the power line networking signals from crossing into the main power grid, but it does little to stop signals in one of the homes it powers from propagating to another home. Thus networking signals generated in one home may show up (albeit attenuated) on the power line in another home. This creates urgent concerns about privacy, similar to those encountered in wireless systems."

'Distributivni transformator' koji u SAD snabdeva u proseku 6 kuca strujom, zaista blokira signal ali od sirenja u glavnu elektricnu mrezu i kuce koje su snabdevane strujom od strane drugih 'distributivnih transformatora'. I dalje ostaje problem sta sa ostalih 5 kuca povezanih na isti 'distributivni transformator'. Kod njih takodje postoje brojila (doduse digitalna koja bi uskoro i kod nas trebalo da pocnu da se primenjuju ako se ne varam) tako da nisam siguran koliko je istinita ta prica za brojila.

Ovaj pojam 'distributivnog transformatora' mi je pomalo nejasan. Kapiram da su to one kucice sa visokim naponima u nasim naseljima, ali one kod nas strujom snabdevaju mnogo vise od 6 kuca tako da ispada da mi imamo jos veci problem?!?!
[ aleksandaraleksandar @ 31.08.2004. 21:46 ] @
ja i dalje ne kapiram gde je problem? moze li neko da mi pojasni?
[ Paxy @ 01.09.2004. 08:22 ] @
Vidi ovako,
U Svetu Kompjutera (avgustovski broj cinimi se), je objavljen clanak o tome sta i kako moze MSI ov uredjaj za mreze preko elektricnih vodova.
Oni su i testirali u zgradi - visespratnici.
U upustvu pise da uredjaj ne moze vise od 300m (kroz kablove) sto najcesce znaci da ne moze izmedju dva sprata jer, da bi dosao do drugog sprata mora prvo doci do sanduka, sto znaci dupli put.
Uspeli su da povezu na nekim spratovima ali im je veza bila losa (oko 4 mbps).

Moja pretpostavka je da bi kuce, na rastojanju do 100 metara, trebalo normalno da se povezu, jer se izmedju njih nalazi samo zajednicki sanduk ili bandera.

Mada posto ovaj uredjaj kosta 50e komad smatram da za te pare bolje razvucite kabl za eternet.
[ aleksandaraleksandar @ 01.09.2004. 21:30 ] @
mene zanima onaj deo sa "ormanima". zasto nece da radi net?
[ grozda @ 09.02.2010. 09:47 ] @
D-Link DHP-303

http://www.naslovi.net/2010-01...link-dhp-303-powerline/1477391

da li je neko probao ovo i kakva su ogranicenja za jedan stan ?



i koja je cena ovoga? Ima li ga kod nas?
[ bgillegal @ 10.02.2010. 13:39 ] @
Probao sam netgear i rade po principu da komuniciraju preko zajednicke 0. Mreza se stiti tako sto 2 ili vise uredjaja razmene jedan kljuc tako da ne postoji varijanta da vam se neko ubaci u mrezu.
[ ra_rasa @ 17.02.2010. 16:02 ] @
Citat:
grozda: D-Link DHP-303

http://www.naslovi.net/2010-01...link-dhp-303-powerline/1477391

da li je neko probao ovo i kakva su ogranicenja za jedan stan ?



i koja je cena ovoga? Ima li ga kod nas?


I mene zanima, intresantno je za malo veći stan i naravno manjak kablova
[ FOX028 @ 24.08.2011. 17:02 ] @
Da ne bi otvarao novu temu postavicu pitanje ovde. Da li je neko koristio ovaj uredjaj http://www.tplink.com/common/subject/powerline/TL-PA211/ interesuje me da li moraju obe uticnice biti na istoj fazi ili ne.
[ prle21 @ 23.04.2012. 22:21 ] @
Ja sam takođe načuo da ovi uređaji za komunikaciju koriste 0.
Znači ako je to tačno, po zgradama postoje satovi (brojila) ali su svi zakačeni za jednu zajedničku 0.
Osigurači prekidaju faze ali je 0 zakačena za jedan zajednički vod doveden u zgradu.
Po tome bi trebalo da glavna prepreka budu: kvalitet instalacije i udaljenost,
ne znam zašto bi brojila predstavljala problem ako se za komunikaciju koristi 0 ?
Ako neko ima neku informaciju o ovome ne bi bilo loše da podelimo,
koliko je tačno da se koristi 0 za komunikaciju jer mi se čini da je to ključno u ovom slučaju ??
[ valjan @ 25.04.2012. 11:37 ] @
I ja upravo istražujem ovu temu jer selimo firmu na novu lokaciju i biće potrebno umrežiti tri sprata, i izbeći po mogućstvu varijantu sa bušenjem. Za sad znam da TP-Link traži da sve bude na istoj fazi, i da Netgear koristi nulu, ali ću više detalja znati ovih dana. Zna li neko više detalja o brzini i pouzdanosti ovih rešenja, znam da su neki moji bivši klijenti u Londonu povremeno imali problema sa uređajima, a na netu nisam našao neke preterano objektivne analize.
[ prle21 @ 18.05.2012. 15:44 ] @
Ja sam uzeo na ispitivanje dva uređaja,
u pitanju je "D-Link DHP-500AV" koji navodno radi na 500Mb/s,
zaključak je da je unutar stana naravno radio besprekorno ali kada sam probao sa komšijom do mene
brzina je bila u proseku oko 4Mb/s što je očajno,
izgleda da je problam najviše u tome kada signal treba da pređe sa jednog strujnog sata na drugi,
verovatno se, zbog silnih spojeva na brojilima, drastično gubi signal između ovakva dva uređaja.
Zaključak je da verovatno može da radi po spratovima ali samo ako su svi zakačeni na isto brojilo,
ako treba da pređe sa jednog na drugo - uspostavi se komunikacija ali bash jedva, takoreći "useless" :/
[ valjan @ 19.05.2012. 05:03 ] @
@prle21 - da li oba uređaja moraju biti na istoj fazi ili je dovoljno ubosti ih bilo gde unutar kućne instalacije?

Mi smo inače digli ruke od ovoga i implementirali WiFi opciju, jer ovi domaći komercijalisti ili nemaju pojma šta prodaju i kako radi, ili se zbog slabog interesovanja kupaca mora čekati nedeljama da uvezu dovoljan broj uređaja, ne isplati im se da drže na stanju...